The terminal strip is, located on the mechanical input side. The cable coming from
the control head must be connected to the input side.
A pointer is provided on the shaft to indicate its position,
since the bracket can be installed in six different ways. The lever
must be removed to coincide with the bracket and cable lead. The pointer
must be not removed since it is the only indication for mid position. On
the output side, the bracket can be installed in eight different ways.
A 3" stroke cable can be installed on the input side and a 4" cable
can be on the output side. By installing the input cable (3" stroke) on the
second hole from the end of the input lever and installing the output cable on the
last hole on the actuator lever, it will increase the stroke to 3.75".
On long cable runs it is more than likely that there will be a lot of lost
motion in the incoming cable and by arranging the cable on lever the
motion can be regained.
|